volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Battery Temperature Sensor > < Starter Relay|Locations|Page 13414
Page 1
background image

Battery Cable: Service and Repair

Cable, battery to generator

Operation number: 37213-2

Note! Some variation in the illustrations may occur, but the essential information is always correct.

Removal

Note! Some variation may occur. However, the essential information in the illustrations is always correct.

Remove the following items:

-

battery negative lead.  Refer to: See: Service and Repair/Procedures/Battery, Disconnecting

-

the air cleaner (ACL).  Refer to: Air filter module See: Engine, Cooling and Exhaust/Engine/Tune-up and Engine Performance Checks/Air Cleaner
Housing/Service and Repair 

-

connection to battery. Torque: Battery lead to battery lead terminal, 14 Nm

-

nut on starter motor. Torque: Starter motor B+ terminal, 15 Nm

-

the clamp, x 1

-

1 clip

-

the lead.

Installation

To install, reverse the removal procedure

Battery Temperature Sensor > < Starter Relay|Locations|Page 13414