background image

Remove the climate housing drain and inspect to ensure the sound insulation material is not too close to drain.

NOTE:

Water on this material causes swelling

The minimum distance between the end of the drain and the sound proof insulation should be 1/4 inch (5.8 mm).

NOTE:

When reinstalling the drain, ensure there are no kinks in the hose and the assembly is fitted correctly.

Adjustment of the heat shield

The drain for the climate unit is located in this area.

Vehicles with two wheel drive, loosen the cross member as shown here.