V70 GL L5-2.4L VIN 55 B5254S (1998)
Leak Detection Valve: Service and Repair
Removing EVAP canister shut-off valve
-
Disconnect connector
-
Remove 2 clamps by the EVAP canister and rear axle joint.
Removing clamp:
-
squeeze clamp with a pipe wrench. Hold in place.
-
pry apart with a small screwdriver.
Note: These are reusable.
-
Disconnect hoses.
-
Remove rubber mounting from bracket.
Installing EVAP canister shut-off valve
-
In reverse order of removal.
Installing clamp:
-
squeeze the clamp with a pipe wrench until it locks.
Note! Use a new screw clip at the EVAP canister. Reuse clamp at the rear axle joint.