volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Air Injection Pump Relay > < Air Injection Pump|Service and Repair|Page 3749
Page 4
background image

Disconnect the rubber hose to the relief valve and start the engine.
Check that no engine exhausts flow backwards into the pump.
If exhaust gases flow backwards the relief valve is defective and should be changed.
In connection with this test use compressed air to clean the system to the engine with the engine running.

Air Injection Pump Relay > < Air Injection Pump|Service and Repair|Page 3749