volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Differential Case > < Carrier Bearings|Service and Repair|Page 4900
Page 4
background image

Checking Runout 

-

Check flange axial runout.

NOTE: This check must always be carried out when replacing pinion seal/drive flange or when reconditioning the rear axle.

-

Install dial gauge with magnetic holder to fixture 999 5661

-

Axial runout must not exceed 0.05 mm (0.0019"). If axial runout exceeds this value move the flange on the pinion.

NOTE: Use a new nut every time.

NOTE: Do not exceed a tightening torque of 200 Nm (147.6 ft.lb.). Check axial runout again.

-

Mark up the lowest point (where axial runout is greatest) on the edge of the flange. Use a colored pen. This marking should be as close the viscous
coupling marking as the position of the holes allows.

NOTE: For Drive flange replacement refer to Drive/Propeller shaft section on balancing procedure.  See: Drive/Propeller Shafts, Bearings and
Joints/Service and Repair

Differential Case > < Carrier Bearings|Service and Repair|Page 4900