Leak Detection Valve: Service and Repair

Removing EVAP canister shut-off valve

-

Disconnect connector

-

Remove 2 clamps by the EVAP canister and rear axle joint.

Removing clamp:

-

squeeze clamp with a pipe wrench. Hold in place.

-

pry apart with a small screwdriver.

Note:  These are reusable.

-

Disconnect hoses.

-

Remove rubber mounting from bracket.

Installing EVAP canister shut-off valve

-

In reverse order of removal.

Installing clamp:

-

squeeze the clamp with a pipe wrench until it locks.

Note!  Use a new screw clip at the EVAP canister. Reuse clamp at the rear axle joint.