volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Testing Notes|Page 1941 > < Testing Notes|Page 1939
Page 3
background image

Pressure section above.

Line Pressure Too High

-

Disconnect jumper cable between relay base terminals 1 and 3.

-

Disconnect return line from pressure regulator. Blow into line.

If the cable is OK:
^

Try a new pressure regulator. Then measure line pressure. Proceed to: Measuring Line Pressure section above.

If the line is blocked:
^

Check if the return line is blocked, clean/replace. Then measure line pressure. Proceed to: Measuring Line Pressure section above.

Checking Fuel Filter

-

Squeeze the return line and check is the pressure rises.

CAUTION:  Do not allow pressure to exceed 600 kPa (6.0 kp/cm2)(85.3 psi).

If pressure rises rapidly:
^

Proceed to: Checking Pressure Regulator, Lowering Pressure section below.

If pressure rises slowly:
^

Replace fuel filter.

Testing Notes|Page 1941 > < Testing Notes|Page 1939