volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4372 > < Initial Inspection and Diagnostic Overview|Page 4370
Page 21
background image

Ensure that all lighting is switched off.
Ensure that the diagnostic tool is not connected in the vehicle.
Open the tailgate or trunk lid and bonnet and set the locks to the deadlocked position using a screwdriver for example.
Open the driver's and passenger doors and set the locks to the deadlocked position using a screwdriver for example.
Close the rear doors, remove the key and lock and alarm the vehicle. Never use reduced alarm as it then takes longer for the CAN network to continue in
"sleep mode".
Wait approximately 3 minutes (5 minutes for C70 (06-)) so that the vehicle's standby current consumption drops.

Note! Do not open any doors or the test will have to be restarted from the beginning.

Continue -  Measuring the voltage level on the CAN network. 

-------------------------------------------------

Measuring the voltage level on the CAN network.

General

When measuring the voltage level on the CAN network, it will soon become evident if there are modules in the vehicle that do not continue in "sleep
mode".
The method for measuring the voltage on the CAN network is described below.
The voltage level on the CAN network is carried out using a multimeter.

Measuring

The CAN network must have continued in "sleep mode" after approximately 3 minutes (5 minutes for C70 (06-)). The voltage on the network must be 0
V with the CAN network in "sleep mode".
The voltage is 0,5 to 4 V for a vehicle that communicates over the CAN network.
Voltage measure the CAN network as follows:
Prepare the multimeter for power supply 10 V.

Note! Do not carry out work inside a vehicle equipped with mass movement sensors as the alarm may be triggered.

Measure the voltage on the low speed CAN network by connecting the hand terminal, component number 30656638, in diagnostic tool socket terminals
#3 and #11. Connect the multimeter to the hand terminal and read off the voltage.
Measure the voltage on the high speed CAN network by connecting the hand terminal, component number 30656638, in diagnostic tool socket terminals
#6 and #14. Connect the multimeter to the hand terminal and read off the voltage.

Continue - DONE

-------------------------------------------------

Scan Tool Testing and Procedures

Reading control unit id

Initial Inspection and Diagnostic Overview|Page 4372 > < Initial Inspection and Diagnostic Overview|Page 4370