Continue - Fault Found

-------------------------------------------------

Reverse Light Remains On

Checking reverse light contact

Checking wire and replacement of component

Check the wire between the control unit 1A and reverse light contact 2 (3/10) for a short-circuit to voltage supply as described in Checking wiring and
terminals. Permanent fault See: Testing and Inspection/Component Tests and General Diagnostics/Checking Wiring and Terminals/Checking Wiring and
Terminals. Permanent Fault , and for an open circuit as described in Checking wiring and terminals. Permanent fault See: Testing and
Inspection/Component Tests and General Diagnostics/Checking Wiring and Terminals/Checking Wiring and Terminals. Permanent Fault.
Also check the connectors for a short circuit to voltage supply, as described in Checking wiring and terminals. Permanent fault See: Testing and
Inspection/Component Tests and General Diagnostics/Checking Wiring and Terminals/Checking Wiring and Terminals. Permanent Fault , and for an
open circuit as described in Checking wiring and terminals. Permanent fault See: Testing and Inspection/Component Tests and General
Diagnostics/Checking Wiring and Terminals/Checking Wiring and Terminals. Permanent Fault.
If no fault is found on the wire, check the function of the reversing lamp switch.

Hint: If reverse light contact is closed, the voltage between 1 and 2 on the contact is 0 V.

Do the necessary corrective action.