volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Refrigerant, Draining|Page 2856 > < Refrigerant|Capacity Specifications|Page 2853
Page 1
background image

Refrigerant: Service and Repair
Refrigerant, Draining

Refrigerant, draining

Note! Some variation in the illustrations may occur, but the essential information is always correct.

Warning! Follow the safety instructions for work on the air conditioning system.  Refer to: Refrigerant See: Heating and Air
Conditioning/Service Precautions/Technician Safety Information/Refrigerant 

Note! First read the instructions covering slow and fast leaks. Refer to: AC-system, oil, refilling See: Heating and Air Conditioning/Service and
Repair/AC-System, Oil, Refilling 

Note! Always plug the pipes and connections when working on the climate control system.

Note! The recycling unit must have an oil separator. The oil separator must be of a type that allows the amount of run out oil to be measured.

Note! The ambient temperature must be above 20°C when draining the system.

Note! Always disconnect the battery ground cable when working with the climate control system.  Refer to:  See: Starting and
Charging/Battery/Service and Repair/Procedures/Battery, Disconnecting 

Note! Always use new O-rings lubricated with compressor oil.

When draining refrigerant, the recycling unit can be attached to the service valve for both the high pressure side (HP) (1) and the low pressure side (LP)
(2) at the same time. This is the quickest method.

Check the amount of oil (if any) that has run out when draining the refrigerant.

Refrigerant, Draining|Page 2856 > < Refrigerant|Capacity Specifications|Page 2853