volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Thermostatic Expansion Valve to Connector Block Line|Page 2705 > < Thermostatic Expansion Valve to Connector Block Line|Page 2703
Page 2
background image

Torque: M8, 24 Nm

Installation

Change and lubricate the O-rings with compressor oil.

To install, reverse the removal procedure

Vacuum pump the air conditioning (A/C) system. See:  Vacuum pumping See: Heating and Air Conditioning/Service and Repair/Vacuum Pumping.
Fill the A/C system with refrigerant according to:  Refrigerant, filling See: Heating and Air Conditioning/Service and Repair/Refrigerant, Filling.
Carry out leak detection of the A/C system in accordance with:  Leak detection, tracer agent See: Heating and Air Conditioning/Testing and
Inspection/Component Tests and General Diagnostics/Leak Detection, Tracer Agent  or  Leak tracing, electronic leak tracer See: Heating and Air
Conditioning/Testing and Inspection/Component Tests and General Diagnostics/Leak Tracing, Electronic Leak Tracer.

Carry out a performance test on the climate control system.  Climate control system, check See: Heating and Air Conditioning/Testing and
Inspection/Component Tests and General Diagnostics/Climate Control System, Check.

Thermostatic Expansion Valve to Connector Block Line|Page 2705 > < Thermostatic Expansion Valve to Connector Block Line|Page 2703