volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Reading and Clearing Diagnostic Trouble Codes|Page 728 > < Reading and Clearing Diagnostic Trouble Codes|Page 726
Page 1
background image

Trailer Lighting Module: Pinout Values and Diagnostic Parameters

Connecting Breakout Box, Trailer Module (TRM)

Connecting the breakout box

Special tools:

951 1428 Breakout box  See: Tools and Equipment/951 1428 Breakout Box 
951 2888 16-pin AUD adapter See: Tools and Equipment/951 2888 16-Pin AUD Adapter 
951 1508 Adapter 10-7-5 pin  See: Tools and Equipment/951 1508 Adapter 10-7-5 Pin 

Caution! Avoid touching control module connector pins and corresponding cable harness connectors. There is a risk of electrostatic discharge,
which could damage the control module. Relieve any charge on yourself and the tools to be used by holding the metal part of the tool and
touching part of the body just before starting work.

General information

Visually check the connectors to ensure that the male and female terminals are not damaged and that the cables for the female halves are properly
connected.
The breakout box is designed to facilitate reading off control module output and input signals when the control module is connected as well as resistance
of cables and components when the control module is disconnected. Using a breakout box reduces the risk of unintentionally short-circuiting cables or
damaging connector pins.

Connecting the breakout box

-

Ignition off

-

To expose the connectors for the trailer module (TRM):

Connect breakout box 951 1428 Breakout box  See: Tools and Equipment/951 1428 Breakout Box  to the adapter.

Trailer Module (TRM)

-

Connect adapter 951 2888 16-pin AUD adapter See: Tools and Equipment/951 2888 16-Pin AUD Adapter  to the control module connector C1.

-

Connect adapter 951 1508 Adapter 10-7-5 pin  See: Tools and Equipment/951 1508 Adapter 10-7-5 Pin  to the control module connector C2.

-

For connector C1, terminals #C1:1 - #C1:2 correspond to terminals #31 - #32 on the breakout box.

-

For connector C2, terminals #C2:1 - #C2:5 correspond to terminals #22 - #26 on the breakout box.

Signal Specification, Trailer Module (TRM)

Signal specification

General

All the values given below are between the terminals stated in column 1 and terminal #C2:4 in column 2 (power ground).

Note! It is important to connect the breakout box and check the ground terminals before taking readings.

Reading and Clearing Diagnostic Trouble Codes|Page 728 > < Reading and Clearing Diagnostic Trouble Codes|Page 726