Dome Lamp: Testing and Inspection
Checking the Interior Lighting (1)

Trouble-Shooting Information

Trouble-shooting information

Condition

No diagnostic trouble codes are displayed.

Substitute value

Nothing.

Possible source

-

Open circuit or short circuit to ground on the wire.

Faulty lamp unit.

Fault symptom[s]

-

Interior lighting does not work.

Checking the Interior Lighting (1)

Checking the interior lighting (1)

Checking components and wiring

Control module and rear reading lamp module

Check the cable between control module terminal #15 and rear reading lamp module terminal #2. Check for an open-circuit.
Check the cable between control module terminal #14 and rear reading lamp module terminal #6. Check for an open-circuit.

Control module and roof lamp module

Check the cable between the control module terminal #8 and roof lamp module terminal #2A. Check for an open-circuit. Check for a short-circuit to
ground.

Control module and right / left vanity mirror lighting

Check the cable between control module terminal #8 and right / left vanity mirror lighting terminal #1. Check for an open-circuit. Check for a
short-circuit to ground.
Check the cable between control module #20 and right / left vanity mirror lighting #3. Check for an open-circuit.
Remedy as necessary.
If no fault is found, try replacing the module that is malfunctioning.
This could be:

-

Rear reading lamp module

-

Roof lamp module

-

Right / left vanity mirror lighting.

Other information

-

For further information about signals and other values, see Signal specification See: Body and Frame/Body Control Systems/Testing and
Inspection/Pinout Values and Diagnostic Parameters/Signal Specification/Signal Specification, Upper Electronic Module (UEM) 

-

To connect the breakout box, see Connecting the breakout box See: Body and Frame/Body Control Systems/Testing and Inspection/Pinout Values
and Diagnostic Parameters/Connecting the Breakout Box 

-

To access the vanity mirror lighting, see Bulb vanity mirror, replacing See: Vanity Lamp/Service and Repair 

-

To access or replace the roof lamp module, see Replacing interior lighting See: Service and Repair/Interior Lighting, Replacing 

-

To access or replace the rear reading lamp module, see Bulb, reading lamp, rear, replacing See: Service and Repair/Bulb, Reading Lamp, Rear,
Replacing 

-

Checking wiring and terminals See: Testing and Inspection/Component Tests and General Diagnostics/Checking Wiring and Terminals.

Checking the Interior Lighting (1)|Page 16287 > < Daytime Running Lamp Relay|Locations|Page 16282