volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Checking Fuel and Residual Pressures|Page 4349 > < Fuel Pressure|Specifications
Page 1
background image

Fuel Pressure: Testing and Inspection
Checking Fuel and Residual Pressures

Checking fuel and residual pressures

Note! To check the fuel and residual pressures for S70/V70/C70, see See: Powertrain Management/Fuel Delivery and Air Induction/Testing and
Inspection/Fuel System Pressure, Checking

Note! For vehicles with demand activated fuel pumps (FP), see VIDA vehicle communication Quick test of fuel pump (FP).

Measuring the line pressure

-

Connect the pressure gauge according to Fuel pressure gauge See: Fuel Pressure Gauge 

-

Remove the soundproofing panel

-

Remove the fuel pump (FP) relay (CMI 12 in the passenger compartment)

-

Connect a cable to the relay base as illustrated.

Read off the line pressure from the pressure gauge. The line pressure must be 375-395 kPa.
Check the residual pressure if the fuel pressure is OK.
Remedy as necessary.

Other information:

-

For the location of and to replace the fuel pump (FP) relay, see Central electronic module (CEM), replacing See: Body and Frame/Body Control
Systems/Body Control Module/Service and Repair 

-

For the location of and to replace the fuel pump (FP), see See: Powertrain Management/Fuel Delivery and Air Induction/Fuel Pump/Service and
Repair 

-

For the location of and to replace the fuel filter, see Replacing the fuel filter See: Fuel Filter/Service and Repair 

-

To disconnect the pressure gauge, see Fuel pressure gauge See: Fuel Pressure Gauge 

Checking the residual pressure

Checking Fuel and Residual Pressures|Page 4349 > < Fuel Pressure|Specifications