volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Variable Valve Timing Actuator|Locations|Page 3235 > < Variable Valve Timing Actuator|Locations|Page 3233
Page 5
background image

This setting is done on a cold engine. A suitable temperature is approximately 20° C/68° F. At higher temperature, for example if the engine is warm or
ambient temperature is higher, the indicator assumes a position farther to the right. The illustration shows the indicator position when setting the belt
tensioner at approximately 20° C/68° F.

Note! There are two different tensioners depending on model year.

Fix the belt tensioner center screw in position and turn the belt tensioner eccentric counterclockwise until the tensioner indicator passes the marked
position and reaches the end position. Then turn the eccentric back so the indicator reaches the marked position illustrated. Tighten the center screw. See
Tightening torque, B6324S See: Specifications/Mechanical Specifications/Tightening Torque.
Check that the indicator is in the correct position.

Tightening

Variable Valve Timing Actuator|Locations|Page 3235 > < Variable Valve Timing Actuator|Locations|Page 3233