volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Wastegate Actuator|Testing and Inspection|Page 5903 > < Wastegate Actuator|Testing and Inspection|Page 5901
Page 3
background image

Connect

-

manometer 999 5646 Pressure gauge See: Tools and Equipment/999 5646 Pressure Gauge to the pressure regulator hose

-

pressure regulator 999 5544 Regulator See: Tools and Equipment/999 5544 Regulator to the manometer.

Note! When taking readings the manometer must always hang vertically from its hook. This is to ensure that the correct values are obtained.
Set the three-way junction handle to the middle position.

Screw out the adjustment screw for the pressure regulator completely.
Connect compressed air to pressure regulator.
Screw in the adjustment screw for the pressure regulator so that the manometer displays the value applicable to the relevant engine, according to the table
below.
The three-way junction connector has a vent (drilled hole) where it connects to the pressure regulator to facilitate setting the correct pressure.

Checking and adjusting push rod

Wastegate Actuator|Testing and Inspection|Page 5903 > < Wastegate Actuator|Testing and Inspection|Page 5901