Headlamp Alignment Sensor: Testing and Inspection

Calibrating the position sensor for Bi-Xenon lamps

The position sensor must be calibrated when replacing the rear electronic module (REM) or position sensor for the Bi-Xenon lamps.

Note! If the vehicle is equipped with Four-C, calibration must be carried out via suspension module (SUM).

-

Someone must sit in the driver's seat during calibration. The person must weigh at least 75 kg. Ensure that the vehicle is unladen and is on a flat
surface

-

Ignition on

-

Click on the VCT2000 symbol

-

Calibrate the position sensor.

Note! Diagnostic trouble code (DTC) REM-8F12 is stored when the rear electronic module (REM) is replaced by a new. After calibrating the
position sensor, erase the diagnostic trouble codes (DTCs) in the rear electronic module (REM).

Continue - DONE