Communications Control Module: Component Tests and General Diagnostics

Checking the Supply/Ground Terminal, Multimedia Module (MMM)

Checking the voltage / ground terminal

Checking the power supply and ground terminals

Power supply multimedia module (MMM)

The multimedia module (MMM) is supplied with power via a power supply input on the control module.
When the ignition is on, the power input is powered and the multimedia module (MMM) is in active mode.

-

Power input 1 (terminal #21 (#A1)) is supplied with power via a relay on the central electronic module (CEM). The relay is powered via a fuse
from the battery. The relay coil can be diagnosed by the central electronic module (CEM). The multimedia module (MMM) will not be activated if
there is an open-circuit.

Checking the power supply

Check the power supply cable from the battery to the relay on the central electronic module (CEM) and from the relay for the multimedia module
(MMM) terminal #21 (#A1). Check for an open-circuit. Check for loose connections. Check for contact resistance and oxidation. Check the fuse. The
voltage must be approximately battery voltage when the ignition is on.

Ground terminal multimedia module (MMM)

The multimedia module (MMM) has a ground input. The ground input from the control module is connected via a ground lead to the ground terminal in
the car body. See the relevant wiring diagram for further information about ground terminals.

-

Ground input 1 (terminal #25 (#A5) is power ground and is connected to the ground terminal in the car body.

Checking ground terminal

Check the ground lead between multimedia module (MMM) terminal #25 (#A5) and the ground terminal. Check for an open-circuit. Check for loose
connections. Check for contact resistance and oxidation. With the ignition on, the drop in voltage between the ground connection for the multimedia
module (MMM) and the ground terminal must not be greater than 0.5 V.
Remedy as necessary.

Other information:

-

Checking wiring and terminals See: Testing and Inspection/Component Tests and General Diagnostics/Checking Wiring and Terminals 

-

To connect the breakout box, see Connecting the breakout box See: Pinout Values and Diagnostic Parameters/Connecting the Breakout
Box/Connecting the Breakout Box, Multimedia Module (MMM) 

-

For information about signals, see Signal specification See: Pinout Values and Diagnostic Parameters/Signal Description/Signal Description,
Multimedia Module (MMM) 

-

See the relevant wiring diagram for information about circuit and ground terminals in the bodywork.

Reading and Clearing Diagnostic Trouble Codes|Page 190 > < Reading and Clearing Diagnostic Trouble Codes|Page 188