Positive Crankcase Ventilation: Description and Operation

The blow-by gasses and vapors in the crankcase are recycled by being drawn into the combustion chambers and burned there rather than being vented to
the atmosphere. As the vapors leave the crankcase, they pass through a trap. This device separates liquid oil from the vapors and returns the oil to the
sump. The vapors then enter a hose connecting the trap to the air cleaner. A flame trap in the hose prevents the vapors in the crankcase from being
ignited in case of carburetor backfire. A baffle at the air cleaner disperses the vapors as they enter. The vapors become part of the intake charge, entering
through the carburetor and intake manifold into the combustion chambers.