Starter Motor: Testing and Inspection

Starter Performance Test

1. Disconnect the wires from the S terminal and the M terminal.
2. Make the connections as described using as heavy a wire as possible (preferably equivalent to the wire used for the vehicle). To avoid damaging

the starter, never leave the battery connected for more than 10 seconds.

3. Connect the battery as shown. Be sure to disconnect the starter motor wire from the solenoid. If the starter pinion moves out, it is working

properly.

4. Disconnect the battery from the M terminal. If the pinion does not retract, the hold-in coil of the solenoid is working properly.

5. Disconnect the battery from the starter body. If the pinion retracts immediately, it is working properly.
6. Clamp the starter firmly in a vise.