7. Check for continuity between the No. 3 terminal of climate control unit connector A (12P) and body ground.

Is there continuity?

YES - Check for loose wires or poor connections at climate control unit connector A (12P). If the connections are good.substitute a known-good
climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit.

NO - Check for an open in the wire between the climate control unit and body ground. If the wire is OK, check for poor ground at G401.