acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Refueling Control Valve, Evaporative System|Locations|Page 6148 > < Refueling Control Valve, Evaporative System|Locations|Page 6146
Page 2
background image

4. Disconnect the vacuum hoses (A) from the EVAP canister (B), and then plug the ports with plugs (C).
5. Disconnect the vacuum hose (D) from the EVAP canister vent shut valve (E), and connect a vacuum pump to the vacuum hose.
6. Pump the vacuum pump 80 times.

-

If the vacuum holds, go to step 7.

-

If the vacuum does not hold, go to step 9.

7. Connect a second vacuum pump to the fuel tank vapor signal tube (A).
8. Apply vacuum (1 pump) to the fuel tank vapor signal tube (A), then check the vacuum on the pump in step 6.

-

If the vacuum holds, replace the fuel tank vapor control valve.

-

If the vacuum is released, the fuel tank vapor control valve is OK. Go to step 10.

9. Disconnect the fuel tank vapor quick disconnect from the EVAP canister, then plug the port on the canister. Reapply vacuum (80 pumps).

-

If the vacuum holds, replace the fuel tank vapor control valve.

-

If the vacuum does not hold, inspect the EVAP canister vent shut valve O-ring. If the O-ring is OK, replace the EVAP canister and repeat step
4.

Refueling Control Valve, Evaporative System|Locations|Page 6148 > < Refueling Control Valve, Evaporative System|Locations|Page 6146