18. Check for continuity in each direction, between the B terminal (A) and P terminals (B), and between the E terminal (C) and P terminals of each 

diode pair. All diodes should have continuity in only one direction. Because the rectifier diodes are designed to allow current to pass in only one
direction, and the rectifier is made up of eight diodes (four pairs) (six diodes (three pairs) for '00-03 models), you must test each diode in both
directions for continuity with an ohmmeter that has diode checking capability: a total of 16 checks (12 checks for'00-03 models).
-

If any diode is faulty, replace the rectifier assembly. (Diodes are not available separately.)

-

If all the diodes are OK, go to step 19.

Alternator Brush Inspection

19. Measure the length of both brushes (A) with a vernier caliper (B).

-

If either brush is shorter than the service limit, replace the brush assembly.

-

If brush length is OK, go to step 20.

Alternator Brush Length:
Standard (New): 10.5 mm (0.41 in.)
Service Limit: 1.5mm (0.06 in.)

Rotor Slip Ring test

Alternator|Removal and Installation|Page 8440 > < Alternator|Removal and Installation|Page 8438