acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Shift Control Solenoid Valves A and C Test|Page 7017 > < Shift Control Solenoid Valves A and C Test|Page 7015
Page 1
background image

Shift Solenoid: Testing and Inspection
Shift Solenoid Valve B Test

Shift Solenoid Valve B Test 

1. Disconnect the connector from the shift solenoid valve B.
2. Measure shift solenoid valve B resistance at the solenoid valve connector (blown).

STANDARD: 12 - 25 Ohms 

3. Replace the shift solenoid valve B if the resistance is out of standard.
4. If the resistance is within the standard, connect the No. 2 terminal of the shift solenoid valve B connector to the battery positive terminal and

connect the No. 1 terminal to the battery negative terminal. A clicking sound should be heard.  Replace the shift solenoid valve B if no clicking
sound is heard.

Shift Control Solenoid Valves A and C Test|Page 7017 > < Shift Control Solenoid Valves A and C Test|Page 7015