acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Power Window Motor > < Recalls for Power Window Control Module:|01-019|Page 15302
Page 1
background image

Power Window Control Module: Testing and Inspection

Resetting the power window control unit

Resetting the power window control unit is required after performing the following procedures:

-

Disconnecting the battery.

-

removing the No. 1 (20 A) fuse in the driver's under-dash fuse/relay box.

-

Disconnecting the 18P connector from the power window control unit.

-

Removing the window regulator, glass or glass run channel.

1. Make sure the glass is installed properly.
2. Turn the ignition switch OFF.
3. Remove the No. 1 (20 A) fuse in the driver's under-dash fuse/relay box.
4. Turn the ignition switch ON (II) on for 2 seconds, then turn it OFF. Reinstall the No. 1 (20 A) fuse in the driver's under-dash fuse/relay box.
5. Make sure the driver's window does not work in AUTO with the ignition switch ON (II).
6. Turn the ignition switch ON (II).
7. Move the driver's window all the way down by using the driver's switch.
8. Move the driver's window all the way up by using the driver's switch, when the window reaches the top, hold the driver's window switch in the UP

position for 2 seconds.

*

If the window does not work in AUTO, reset the power window master switch according to the above procedures again.

Power Window Motor > < Recalls for Power Window Control Module:|01-019|Page 15302