3.5RL V6-3474cc 3.5L (2001)
Malfunction Lamp / Indicator: Description and Operation
Self-diagnosis System
A self-diagnosis circuit is built into the SRS unit; when the ignition switch is turned ON (II), the SRS indicator light comes on and goes off after about
six seconds if the system is operating normally.
If the light does not come on, or does not go off after six seconds, or if it comes on while driving, it indicates an abnormality in the system. The system
must be inspected and repaired as soon as possible.
For better serviceability, the SRS unit memory stores the cause of the malfunction, and the unit is connected to the data link connector (DLC). This
information can be read with the Honda PGM Tester when it is connected to the DLC (16P).