background image

Thermostat: Testing and Inspection

Testing 

Replace the thermostat if it is open at room temperature.

To test a closed thermostat:
1. Suspend the thermostat in a container of water as shown.
2. Heat the water and check the temperature with a thermometer. Check the temperature at which the thermostat first opens, and at which it is fully

open.

CAUTION:  Do not let the thermometer touch the bottom of the hot container.

3. Measure lift height of the thermostat when it is fully open.

STANDARD THERMOSTAT 
Lift height: above 8.0 mm (0.31 in.)
Starts opening: 169-176°F (76-80°C)
Fully open: 194°F (90°C)
 

Mechanical Specifications|Page 2791 > < Mechanical Specifications|Page 2789