5. Measure taper at the edges of each journal.
-
The difference between measurements on each journal must not exceed the standard.
Journal Taper
Standard (New): 0.005 mm (0.0002 in.)
6. Measure runout on the No. 2 journal of each balancer shaft to make sure the balancer shafts are not bent.
Balancer Shaft Total Indicated Runout
Standard (New): 0.02 mm (0.001 in.)
Service Limit: 0.03 mm (0.001 in.)
7. Measure the diameters of the balancer shaft journals.