CL L4-2156cc 2.2L SOHC F22B1 MFI (1997)
Lock-Up Control Solenoid Valve: Service and Repair
NOTE: Lock-up control solenoid valves A and B must be removed/replaced as an assembly.
1. Remove the mounting bolts and lock-up control solenoid valve assembly.
2. Clean the mounting surface and fluid passages of the lock-up control solenoid valve assembly, and install a new lock-up control solenoid valve
A/B with a new filter/gasket.
3. Check the connector for rust, dirt or oil, then reconnect the connector securely.