CL L4-2156cc 2.2L SOHC F22B1 MFI (1997)
Shift Control Solenoid Valve: Service and Repair
NOTE: Shift control solenoid valves A and B must be removed/replaced as an assembly.
1. Remove the mounting bolts and shift control solenoid valve assembly.
2. Clean the mounting surface and fluid passages of the shift control solenoid valve assembly, and install a new shift control solenoid valve A/B with
a new filter/gasket.
3. Check the connector for rust, dirt or oil, then reconnect the connector securely.