acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Sunlight Sensor Test|Page 8243 > < Solar Sensor, HVAC|Specifications|Page 8240
Page 1
background image

Solar Sensor: Testing and Inspection
Sunlight Sensor Test

Turn the ignition switch ON (II). Measure the voltage between the terminals with the (+) probe on the No. 1 terminal and the (-) probe on the No. 2
terminal with the 2P connector connected. Voltage should be;

-

3.7 ± 0.2 V or more with the sensor out of direct light.

-

3.6 ± 0.2 V or less with the sensor in direct sunlight.

NOTE:  The voltage will not change under the light of a flashlight or a fluorescent lamp.

Sunlight Sensor Test|Page 8243 > < Solar Sensor, HVAC|Specifications|Page 8240