CL TYPE S V6-3.2L SOHC (2001)
Security Lamp/Indicator: Testing and Inspection
Safety Indicator Input Test
1. Remove the gauge assembly
2. Disconnect the 30P connector A and 14P connector C from the gauge assembly.
3. Inspect the connector and socket terminals to be sure they are all making good contact.
-
If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
-
If the terminals look OK, go to step 4.
4. Make these input tests at the connectors.
-
If any test indicates a problem, find and correct the cause, then recheck the system.
-
If all the input tests prove OK, go to step 5.
5. Reconnect the connectors to the gauge assembly, and perform the following input tests at the appropriate connector.
-
If any test indicates a problem, find and correct the cause, then recheck the system.
-
If all the input tests prove OK, the gauge internal circuit must be faulty.