TCS NO valve open, TCS NC valve closed, inlet valve closed, outlet valve open.
Caliper fluid flows through the outlet valve to the reservoir.
TCS Control
Pressure intensifying mode
TCS NO valve closed, TCS NC valve open, inlet valve open, outlet valve closed, pump motor ON.
The reservoir and master cylinder fluid is pumped out by the pump, through the damping chamber, to the front caliper.
Pressure retaining mode
TCS NO valve open, TCS NC valve open, inlet valve closed, outlet valve closed, pump motor ON.
Front caliper fluid is retained by the inlet valve and outlet valve.
Pressure reducing mode