Outside Temperature Display: Testing and Inspection

Outside Air Temperature Indicator Test

Troubleshooting:

If the indicator displays "---" for more than two seconds after selecting the outside air temperature display mode, check for an open in the BRN/WHT
wire between the gauge and the outside air temperature sensor or the GRY wire between the gauge assembly and the climate control unit.

Calibration:

The outside air temperature indicator's displayed temperature can be recalibrated ±3 ° to meet the customer's expectations.

1. Turn the ignition switch ON (II).

2. Push and hold the reset and select buttons for 10 seconds. While you continue to hold the buttons, the display will scroll through temperature

settings from +3 ° to -3 ° as shown.

3. When the desired correction value appears on the display, release the buttons, and the recalibrated outside air temperature will be displayed.

If the outside temperature indicator display is off by more than three degrees of the desired value, turn the ignition switch OFF and repeat steps 1 -
3.

NOTE:  To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the
sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the
true temperature.