CL TYPE S V6-3.2L SOHC (2001)
Is there continuity?
YES - Repair short in the wire between ignition coil and PCM.
NO - Go to step 8.
8. Connect the PCM 31P connector.
9. Measure the voltage at the No.1 terminal of each ignition coil 3P connector with the ignition switch to start (III).
Is there approx. 0.5 V?
YES - Replace the ignition coil.
NO - Repair open in the wire between ignition coil and PCM.