acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Electrical - GR8 Battery Diagnostic Station Update Info.|Page 8523 > < Electrical - GR8 Battery Diagnostic Station Update Info.|Page 8521
Page 7
background image

^

Bad Cell Replace - There is an internal problem with the battery. Replace it.

11. The screens toggle back and forth until you turn off the analyzer. To print the test results, press BACK. To return to the main menu, press CLEAR.

NOTE:

^

If you need to submit a warranty claim, enter the 10-digit test code into the first two Diagnostic Trouble Code fields on the warranty claim.

^

If you enter the wrong CCA, or do not use the most current software version, your claim may be rejected.

^

The test results must state Replace Battery or Bad Cell Replace for a warranty battery replacement claim to be approved.

USING THE GR8 DIAGNOSTIC MODE

NOTE:

^

Use the GR8 diagnostic mode when the ED-18 indicates GR8 DIAGNOSTIC NEEDED.

^

For set up, customizing, and other available features, refer to the GR8 instruction manual; besides the one that comes with the GR8, the GR8
instruction manual is also available online. Select GENERAL PUBLICATIONS, select Tool Information, then select GR8-1100P Battery
Diagnostic Station Instruction Manual from the list.

^

Make sure the setup has been completed, and that the GR8 is updated to the most current software. The date and software version is very
important for the proper result. Your warranty claim may not be paid if this information is wrong. See Tool Requirements under REQUIRED
TOOLS for more information.

1. Plug in the GR8.

2. Connect the leads to the battery's positive and negative terminals.

Electrical - GR8 Battery Diagnostic Station Update Info.|Page 8523 > < Electrical - GR8 Battery Diagnostic Station Update Info.|Page 8521