acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Sensors and Switches - Powertrain Management > < Igniter <--> [Ignition Control Module]|Testing and Inspection|Page 1600
Page 3
background image

5.

Check for continuity between terminals A and B (Integra) or C and D (Legend) of igniter unit, Figs. 7 and 8. Continuity should exist in one
direction only.

6.

Connect ohmmeter positive lead to terminal D (terminal A on Legend) of igniter and negative lead to igniter case, then check resistance of igniter.
Resistance should be greater than 50,000 ohms at room temperature.

7.

If resistance is not as specified in previous step, replace igniter.

Sensors and Switches - Powertrain Management > < Igniter <--> [Ignition Control Module]|Testing and Inspection|Page 1600