Integra L4-1678cc 1.7L DOHC (VTEC) FI (1992)
Hydraulic Control Assembly - Antilock Brakes: Testing and Inspection
Fig. 66 Solenoid Leak Test
Fig. 69 Front & Rear Solenoids
1.
Connect suitable circuit tester between black and yellow or yellow and yellow terminals of accumulator pressure switch connector.
2.
Connect positive lead of fully charged 12 volt battery to red/whiter terminal of power unit motor connector (Yellow) and negative lead to green
terminal. Install switch within positive lead, Figs. 66 and 69.
3.
Turn switch on to allow sufficient pressure to build up in accumulator, then check for continuity. If continuity is indicated, run power unit for four
more seconds, then turn switch off.
4.
After switch is off for one minute, recheck continuity, ensuring pipe joint is secure. A faulty solenoid is indicated, if continuity is not present.