Integra L4-1678cc 1.7L DOHC (VTEC) FI (1992)
Inspection
1. Inspect the surface and bearing surface for wear and damage, then measure the countershaft at points A, B, and C.
Standard:
A: 24.980-24.993 mm (0.9835-0.9840 in)
B: 36.984-37.000 mm (1.4561-1.4567 in)
C: 33.000-33.015 mm (1.2992-1.2998 in)
Service Limit:
A: 24.940 mm (0.9819 in)
B: 36.930 mm (1.4539 in)
C: 32.950 mm(1.2972 in)
If any part of the countershaft is less than the service limit, replace it with a new one.
2. Inspect for runout.
Standard: 0.02 mm (0.001 in)
Service Limit: 0.05 mm (0.002 in)
NOTE: Support the countershaft at both ends as shown in image.
If the runout exceeds the service limit, replace the countershaft with a new one.
Reassembly
CAUTION:
-
Press the 4th and 5th gears on the countershaft without lubrication
-
When installing the 4th and 5th gears. support the shaft on steel blocks and install the gears using a press.
-
Install the 4th and 5th gears with a maximum pressure of 26 kN (2,600 kg, 5.720 lbs).