Integra GS-R Coupe L4-1797cc 1.8L DOHC (VTEC) MFI (1997)
Crankshaft: Testing and Inspection
Crankshaft Runout
NOTE:
-
Clean the crankshaft oil passages with pipe cleaners or a suitable brush.
-
Check the keyway and threads.
1. Measure runout on all main journals to make sure the crankshaft is not bent.
2. The difference between measurements on each journal must not be more than the service limit.
Crankshaft Total Indicated Runout:
-
Standard (New): 0.03 mm (0.001 inch) max.
-
Service Limit: 0.05 mm (0.002 inch)