3. Install the rocker arms while inserting the rocker arm shah into the cylinder head.

CAUTION:  After installing the rocker shaft orifice, try to turn the rocker shaft to make sure that the orifice is correctly inserted in the hole of the
rocker shaft. If the orifice is in place, it should not turn.

NOTE:  Remove the rubber band after installing the rocker arms.

4. Clean and install the rocker shaft orifices with new O-rings. If the holes in the rocker arm shaft and cylinder head are not in line with each other,

screw a 12 mm bolt into the rocker arm shaft and rotate the shaft.

NOTE:  The shapes of the rocker shaft orifices for the intake and exhaust are different. The orifices must be installed in the original locations.