acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Hose/Line HVAC > < High Pressure Safety Valve HVAC|Specifications
Page 1
background image

High Pressure Safety Valve HVAC: Service and Repair

Relief Valve / Replacement

1. Remove the relief valve and the O-ring.

NOTE:  Do not let the compressor oil run out. Make sure there is no foreign matter in the system.

2. Install and tighten the relief valve.

a. Clean the mating surfaces.
b. Replace the O-ring with a new one at the relief valve, and apply a thin coat of refrigerant oil (ND-OIL 8: P/N 38899 - PR7 - A01) before

installing it.

NOTE:
-

To avoid contamination, do not return the oil to the container once dispensed, and never mix it with other refrigerant oils.

-

Immediately after using the oil, replace the cap ON the container, and seal it to avoid moisture absorption.

-

Do not spill the refrigerant oil on the car; it may damage the paint; if the refrigerant oil contacts the paint, wash it off immediately.

c. Check for leaks, and insert the cap in the top of the valve.

Hose/Line HVAC > < High Pressure Safety Valve HVAC|Specifications