Integra LS Coupe Blower Motor Relay: Component Information and Location
Blower Motor Relay: Testing and Inspection
RELAY TEST
Normally-Open Type
1. Remove the power relay from its socket.
2. Check continuity between relay terminals.
-
There should be continuity between the A and C terminals when power and ground are connected to the B and D terminals.
-
There should be no continuity when power is disconnected.