Integra LS Coupe L4-1834cc 1.8L DOHC MFI (1997)
3. Remove the ATF pump driven gear shaft, and measure the thrust clearance of the ATF pump driven gear-to-main valve body.
-
ATF pump Drive/Driven Gear thrust (Axial) Clearance:
Standard (New): 0.03 - 0.05 mm (0.001 - 0.002 inch)
Service Limit: 0.07 mm (0.003 inch)