Integra LS Sedan L4-1834cc 1.8L DOHC MFI (1999)
Crankshaft: Service and Repair
Inspection
INSPECTION
NOTE:
-
Clean the crankshaft oil passages with pipe cleaners or a suitable brush.
-
Check the keyway and threads.
ALIGNMENT
-
Measure runout on all main journals to make sure the crank is not bent.
-
The difference between measurements on each journal must not be more than the service limit.
Crankshaft Total Indicated Runout:
Standard (New): 0.03 mm (0.001 inch) max.
Service Limit: 0.05 mm (0.002 inch)
OUT-OF-ROUND AND TAPER
-
Measure out-of-round at the middle of each rod and main journal in two places.
-
The difference between measurements on each journal must not be more than the service limit.
Journal Out-of-Round:
Standard (New): 0.005 mm (0.0002 inch) max.