acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Recirculation Control Motor|Page 6714 > < Recirculation Control Motor|Page 6710
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor

Recirculation Control Motor / Test

1. Connect battery power to the No. 1 terminal of the recirculation control motor, and connect ground to the No. 2 and No. 4 terminals; the

recirculation control motor should run smoothly.

2. Disconnect the No. 2 or No. 4 terminal from ground; the recirculation control motor should stop at FRESH or RECIRCULATE.

CAUTION:  Never connect the battery in the opposite direction.

NOTE:  Don't cycle the recirculation control motor for a long time.

3. If the recirculation control motor does not run in step 1, remove it, and check the recirculation control linkage and door for smooth movement.

If the recirculation control linkage and door move smoothly, replace the recirculation control motor.

Recirculation Control Motor|Page 6714 > < Recirculation Control Motor|Page 6710