acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Blower Unit Removal and Installation|Page 6778 > < Testing For a Short to Ground With A Test Light or DVOM|Page 6775
Page 1
background image

Blower Motor: Service and Repair
Blower Unit Removal and Installation

Blower Unit / Replacement

NOTE:  The blower motor, recirculation control motor and blower resistor can be replaced without removing the blower unit. See: Overhaul

1. Remove the glove box.

2. Remove the four bolts and the glove box frame.

3. Without Air Conditioning

Remove the wire harness clips from the heater duct. Remove the four self-tapping screws and the heater duct.

.With Air Conditioning
Remove the evaporator.

Blower Unit Removal and Installation|Page 6778 > < Testing For a Short to Ground With A Test Light or DVOM|Page 6775