acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Hose/Line HVAC > < Heater-Evaporator Unit Replacement|Page 6961
Page 1
background image

High Pressure Safety Valve HVAC: Service and Repair

Relief Valve / Replacement

1. Recover the refrigerant with Recovery/Recycling/Charging System See: Service and Repair/Discharging & Evacuating System/Refrigerant

Recovery.

2. Remove the relief valve and the O-ring. Plug the opening to keep foreign matter from entering the system and the compressor oil from running out.

NOTE:
-

Do not let the compressor oil run out.

-

Make sure there is no foreign matter in the system.

3. Clean the mating surfaces.
4. Replace the O-ring with a new one at the relief valve, and apply a thin coat of refrigerant oil (ND-OIL 8: P/N 38897-PR7-A01AH or

38899-PR7-A01) before installing it.

5. Charge the system, and test its performance
6. Check for leaks, and insert the cap in the top of the valve.

Hose/Line HVAC > < Heater-Evaporator Unit Replacement|Page 6961