acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Hose/Line HVAC|Specifications|Page 6970 > < Hose/Line HVAC|Specifications|Page 6968
Page 1
background image

Hose/Line HVAC: Service and Repair

The air conditioner system uses HFC-134a (R-134a) refrigerant and polyalkyleneglycol (PAG) refrigerant oil (ND-OIL 8: P/N 38899 - PR7 - A01),
which are not compatible with CFC-12 (R-12) refrigerant and mineral oil. Do not use R-12 refrigerant or mineral oil in this system, and do not attempt to
use R-12 servicing equipment; damage to the air conditioner system or your servicing equipment will result.
Use only service equipment that is U.L.-listed and is certified to meet the requirements of SAE J2210 to remove R-134a from the air conditioner system.

CAUTION:  Exposure to air conditioner refrigerant and lubricant vapor or mist can irritate eyes, nose and throat. Avoid breathing the air conditioner
refrigerant and lubricant vapor or mist.

If accidental system discharge occurs, ventilate work area before resuming service.

WARNING:  Some mixtures of air and R-134a have been shown to be combustible at elevated pressures and can result in fire or explosion
causing injury or property damage. Never use compressed air to pressure test R-134a service equipment or vehicle air conditioner systems.

Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.

REFRIGERATION LINES REPLACEMENT

1. Discharge refrigerant in refrigeration system.

2. Replace faulty hose, pipe or line.

NOTE:
-

Always disconnect the negative cable from the battery whenever replacing air conditioning parts.

-

Keep moisture and dust out of the system. When disconnecting any lines, plug or cap the fittings immediately; don't remove the caps or plugs
until just before you reconnect each line.

-

Before connecting any hose or line, apply a few drops of refrigerant oil to the O-ring.

-

When tightening or loosening a fitting, use a second wrench to support the matching fitting.

3. Torque connections to the specified torque.

Refrigerant Lines, Hoses, Pipes

(1) Discharge hose to the compressor

(6 x 1.0 mm) 9.8 Nm (1.0 kgf.m, 7.2 lbf.ft)

(2) Discharge hose to the condenser

(6 x 1.0 mm) 9.8 Nm (1.0 kgf.m, 7.2 lbf.ft)

(3) Condenser pipe lathe condenser

(6 x 1.0 mm) 9.8 Nm (1.0 kgf.m, 7.2 lbf.ft)

(4) Condenser pipe to the receiver/dryer

(6 x 1.0 mm) 9.8 Nm (1.0 kgf.m, 7.2 lbf.ft)

(5) Receiver pipe A to the receiver/dryer

(6 x 1.0 mm) 9.8 Nm (1.0 kgf.m, 7.2 lbf.ft)

(6) Receiver pipe A to the receiver pipe B

13 Nm (1.3 kgf.m, 9.4 lbf.ft)

(7) Receiver pipe B to the receiver pipe C

13 Nm (1.3 kgf.m, 9.4 lbf.ft)

(8) Receiver pipe C to the evaporator

(6 x 1.0 mm) 9.8 Nm (1.0 kgf.m, 7.2 lbf.ft)

(9) Suction pipe B to the evaporator

Hose/Line HVAC|Specifications|Page 6970 > < Hose/Line HVAC|Specifications|Page 6968