Legend V6-2494cc 2.5L SOHC FI (1986)
Air Door Actuator / Motor: Testing and Inspection
Function Control Motor Does Not Run
Function control motor does not run.
1. Check the No. 22 and No. 26 fuses (engine compartment) and No. 10 fuse (under-dash fuse box).
2. Check the function control motor. If there is no problem, inspect for an open in the wire between the function control motor and function control
unit. If no problem is found, the control unit is defective.